SCHMC

Long-term outcomes of a modified nonflared fully covered self-expandable metal stent for refractory anastomotic biliary strictures after liver transplantation (with video)

Metadata Downloads
Abstract
Objectives: Although fully covered self-expandable metal stents (FCSEMS) are used for the management of anastomotic biliary stricture (ABS) after liver transplantation (LT), there is concern about long-term adverse events such as recurrence of stricture. We evaluated the long-term efficacy of a modified nonflared FCSEMS (M-FCSEMS) compared to plastic stents (PS) for refractory ABS after LT.

Methods: Consecutive patients who underwent placement of an M-FCSEMS (M-FCSEMS group) or multiple PS (PS group) for refractory ABS after LT were enrolled. The primary outcome was the stricture recurrence rate, and the secondary outcomes were technical success, clinical success, and the rate of de novo stricture.

Results: In both groups, technical success was achieved in all patients. The median stent duration was 3.1 months in the M-FCSEMS group and 7.6 months in the PS group (P < 0.001). Clinical success rates were 96.7% (29/30) for the M-FCSEMS group and 94.4% (17/18) for the PS group (P = 0.709). Stent migration occurred in 10.0% (3/30) of the patients before removal of the stent in the M-FCSEMS group, while 27.8% (5/18) of patients in the PS group showed stent migration (P = 0.110). Stricture recurrence occurred in 17.2% (5/29) in the M-FCSEMS group, compared to 47.1% (8/17) in the PS group (P = 0.036). There were no de novo strictures observed in either cohort.

Conclusion: Modified nonflared FCSEMS is effective for relieving refractory ABS after LT, with a low recurrence rate and the absence of de novo stricture after long-term follow-up.
All Author(s)
Jae Woo Park ; Jong Ho Moon ; Yun Nah Lee ; Il Sang Shin ; Jun Chul Chung ; Jaehong Jeong ; Tae Hoon Lee ; Jae Kook Yang ; Young Deok Cho ; Sang-Heum Park
Intsitutional Author(s)
이태훈; 양재국; 박상흠
Issued Date
2025
Type
Article
Keyword
anastomotic biliary stricture; liver transplantation; modified nonflared fully covered self‐expandable metal stent
Publisher
John Wiley & Sons Australia, Ltd
ISSN
0915-5635 ; 1443-1661
Citation Title
Digestive endoscopy
Language(ISO)
eng
DOI
10.1111/den.14990
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/4813
Appears in Collections:
소화기내과 > 1. Journal Papers
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.