- PURPOSE: To introduce the clinical utility of multifocal visual evoked potential (mfVEP) and to assess the waveform from normal Korean subjects.
METHODS: mfVEP with 4 channel recording was performed using the RETIscan(R) system (Roland Consult, Wiesbaden, Germany) for 25 eyes of 25 normal subjects. Amplitudes and implicit times were obtained from ring-shaped 6 areas and 4 sectors. To investigate the false-positive ratio of the examination, stimuli were given with one-half of the CRT monitor completely covered and the results were compared.
RESULTS: Amplitudes of P1, N2 were larger in the central 10degrees area than other areas (p<0.001). Amplitudes were reduced and implicit times were prolonged on peripheral areas. P1 amplitudes were larger in the inferior field. Waves with large amplitudes by noise were recorded in 13.7% of covered areas.
CONCLUSIONS: mfVEP is useful tool to detect local optic nerve damage and rule out the non-organic cause of visual field defect. However, mfVEP results are difficult to interpret due to noise and poor patient cooperation. Standardization of mfVEP is necessary for its application.
- All Author(s)
- H. D. Kim
; S. H. Park
; Y. H. Ohn
- Intsitutional Author(s)
- 김훈동; 온영훈
- Issued Date
- 2010
- Type
- Article
- Keyword
- Amplitude; Area; Multifocal visual evoked potential; Implicit time; Sector
- Publisher
- 대한안과학회
the Korean Ophthalmological Society
- ISSN
- 0378-6471
; 2092-9374
- Citation Title
- 대한안과학회지
Journal of the Korean Ophthalmological Society
- Citation Volume
- 51
- Citation Number
- 4
- Citation Start Page
- 532
- Citation End Page
- 541
- Language(ISO)
- kor
- DOI
- 10.3341/jkos.2010.51.4.532
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/4151
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.